22-7. TORQUE CONVERTER HOUSING/FRONT SUPPORT REPAIR (CONT)
NOTE
If transmission is mounted in stand,
it may only be possible to Install 7 of
11 washers (16) and screws (17). The
remaining  four  screws  will  be
installed
when
transmission
is
removed from stand.
(13) Install seven new lockwashers (16) and screws
(17) holding torque converter housing (7) to
transmission housing (13). Torque to 67-80 lb-ft
(90-108 N m).
WARNING
Adhesive-sealant can bum easily, can
give  off  harmful  vapors,  and  is
harmful to skin and clothing.  To
avoid Injury or death, keep away from
open fire and use in well-ventilated
area. If adhesive-sealant gets on skin
or clothing, wash immediately with
soap and water.
(14) Apply small amount of silicone adhesive-sealant
to two washers (18) and screws (19).
(15) Remove one pitot collector guide screw (8) and
pull up on other pitot collector guide screw (8);
position washer (18) and screw (19).  Tighten
screw until snug.
(16)
Remove other pitot collector guide screw (8)
and position washer (18) and screw (19).
Tighten screw until snug.
(17)
Tighten two screws (19) to 38-48 lb-in. (4.3-5.4
Nm).
f. Follow-On Maintenance
Install torque converter pump (para 22-6).