(29) Check clearance between backplate (38), drive
gear (37), and two driven gears (35) using feeler
gages (40).  Maximum clearance is 0.006 in.
(0.15 mm). If clearance is more than 0.006 in.
(0.15 mm),replace oil pump.
(30) Turn oil pump (33) over.
(31) Coat rubber lip of new seal (41) with lubricating
oil and install seal in pump (33).
(32) Coat new outer seal ring (42) with lubricating oil
and install on backplate (38).
(33) Turn torque converter housing (5) on side with
aid of assistant.
(34) Install oil pump (33) on torque converter housing
(5)  while  assistant  holds  torque  converter
housing (5).
(35) Align screw holes in oil pump (33) with holes on
front support (10).
(36) Install six screws (43) in front support (10) and
oil pump (33) with aid of assistant.