20-2. BLOWER REPAIR (CONT)
NOTE
There  are  12  measurements  for
checking clearance between rotor
lobes and housing, 6 from air inlet
side and 6 from air outlet side.
(51) Place 0.0015 in. (0.38 mm) feeler gage between
one lobe of rotor (8) and housing of blower (10).
(52) Rotate rotors and position gage between one
rotor lobe (31) and housing of blower (10).
(53) Remove feeler gage from between rotor (8) and
housing of blower (10).
(54) Repeat steps (51) thru (53) for other two lobes
of rotor (8) and three lobes of rotor (9).
(55) If clearance is not correct, replace housing of
blower (10).
(56) Position blower (10) so air outlet side is facing
up.
(57) Place 0.005 in. (0.13 mm) feeler gage between
one lobe of rotor (8) and housing of blower (10).
(58) Rotate rotors to position feeler gage between
one rotor lobe (31) and housing of blower (10).
(59) Remove feeler gage from between rotor (8) and
housing of blower (10).
(60) Repeat steps (56) thru (59) for other two lobes
of rotor (8) and three lobes of rotor (9).
(61) If clearance is not correct, replace basic blower
(10).
(62) Position blower (10) with air inlet side up.
(63) Remove four screws (30) and washers (29) from
rear end plate (1).