TM 9-2320-360-34-1
OIL PRESSURE REGULATOR VALVE TEST
(1) Remove oil pressure regulator valve (para 3-22).
(1) WARNING
Dry cleaning solvent P-D-680 is toxic and flammable.
Wear protective goggles and gloves and use solvent
only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes, and don't breathe vapors. Do not use
near open flame or excessive heat. The flash point is
100-138° F (38-50° C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get
medical aid. If solvent contacts eyes, wash eyes with
water and get medical aid immediately.
(2) Clean oil pressure regulator valve with dry cleaning solvent.
(2) WARNING
Compressed air for cleaning purposes will not exceed
30 psi (207 kPa). Use only with effective chip guarding
and personal protective equipment (goggles/shield,
gloves, etc.).
(3) Dry oil pressure regulator valve with compressed air.
(4) Inspect valve inside oil pressure regulator valve for sludge, scoring
and not closing completely.
(5) Install oil pressure regulator valve (para 3-22).
OIL PRESSURE REGULATOR VALVE TEST
(1) Remove oil pressure relief valve (para 3-21).
(3) WARNING
Dry cleaning solvent P--680 is toxic and flammable.
Wear protective goggles and gloves and use solvent
only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes, and don't breathe vapors. Do not
use near open flame or excessive heat. The flash
point is 100-138° F (38-50° C). If you become dizzy
while using cleaning solvent, get fresh air immediately
and get medical aid. If solvent contacts eyes, wash
eyes with water and get medical aid immediately.
(2) Clean oil pressure relief valve with dry cleaning solvent.
(4) WARNING
Compressed air for cleaning purposes will not exceed
30 psi (207 kPa). Use only with effective chip
guarding
and
personal
protective
equipment
(goggles/shield, gloves, etc.).
(3) Dry oil pressure relief valve with compressed air.
(4) Inspect valve inside oil pressure relief valve for sludge, scoring
and not closing completely.
(5) Install oil pressure regulator valve (para 3-21).
2-79
|