TM 9-2320-360-34-1
WARNING
·
Cab weighs 2600 lb (1179 kg). Stay clear of cab when it is supported by lifting
device. If cab falls, serious injury of death may result. Use 10 ft (3 m)
guidelines to help guide cab during removal.
·
Refer to Figure 16-1, Warning Zone Diagram, for proper placement of personnel
when removing cab. Failure to comply may result in serious injury or death to
personnel.
·
Ensure personnel are clear of lifting area. All personnel are within visual sight
of each other and not within 15 ft (4.6 mm) of cab when lifting is in process.
Failure to comply may result in serious injury or death to personnel.
CAUTION
·
Ensure lifting device is centered over cab before lifting. Failure to comply may
result in damage to cab.
·
Ensure all hoses and wire harnesses are disconnected before attempting to lift
cab. Failure to comply may result in damage to equipment.
·
The cab must be lifted 27 in. (68.5 cm) in order to clear chassis components
during removal. In order to accomplish this task, a minimum ceiling height of
approximately 19 ft, 4 in. (5.89 m) is required to remove the cab indoors.
Failure to comply may result in damage to equipment or the facility.
(52)
Remove cab (105) from frame (127) with aid of assistants.
WARNING
Do not allow personnel to work
between jackstands and cab or within
designated danger zones while lifting
device is supporting cab. Failure to
comply may result in serious injury
or death to personnel.
NOTE
Place jackstands 1 ft (30.5 mm)
outside parameter of each cab mount
location. Slide jackstand under cab
mount when cab is approximately 2
in. (5 cm) above jackstand. Lower
cab on jackstands.
(53)
Lower cab (105) and support on four
jackstands (128).
Change 1 16-17
|