TM 9-2320-360-20-3
Section 5
DIAGNOSTIC DATA READER INFORMATION (Contd)
Parameter [9]: VSG SETRPM
Definition:
Indicates the engine set speed for the Variable Speed Governor,
Typical Range: (0 to 2500 RPM) or N/A
Parameter [10]: BOI
Definition:
Beginning of Injection - Specifies the timing of the injection event as the number of degrees crankshaft
rotation before piston TDC. This data is available for engineering purposes only.
Typical Range: (0.0 to 25.5 Degrees) or N/A
Parameter [ll]: OIL TEMP
Definition:
Indicates the temperature of the engine oil that is measured by the Oil Temperature Sensor (OTS) in
degrees Fahrenheit or Celsius.
Typical Range: (-40 to 327 deg F) or (-40 to 150 deg C)
Parameter [12]: COOL TEMP
Definition:
Indicates the temperature of the engine coolant that is measured by the Coolant Temperature Sensor
(CTS) in degrees Fahrenheit or Celsius.
Typical Range: (-40 to 327 deg F) or (-40 to 150 deg C)
Parameter [13]: FUEL TEMP
Definition:
Indicates the temperature of the engine fuel that is measured by the Fuel Temperature Sensor (FTS) in
degrees Fahrenheit or Celsius.
Typical Range: (-40 to 214 deg F) or (-40 to 87 deg C)
Parameter [14]: AIR INLET TEMP
Definition:
Indicates the temperature of the air entering the engine air induction system that is measured by the Air
Temperature Sensor (ATS) in degrees Fahrenheit or Celsius.
Typical Range: (-40 to 214 deg F) or (-40 to 87 deg C)
Parameter (16]: OIL PRS
Definition:
Indicates the engine oil pressure that is measured by the Oil Pressure Sensor (OPS) in PSI or KPa.
Typical Range: (0.0 to 64.0 PSI) or (0 to 448 KPa)
Parameter [18]: BAR0 PRS
Definition:
Barometric Pressure - Indicates the atmospheric pressure in PSI or KPa.
Typical Range: (0.0 to 999.9 PSI) or (0 to 9999 KPa)
Parameter [23]: COOL LEVEL
Definition:
Indicates the coolant level in the reservoir that is measured by the Coolant Level Sensor (CLS).
Typical Range: FULL or LOW
Parameter [25]: ENG LOAD PCT
Definition:
Indicates the percent engine load calculated from engine speed and torque.
Typical Range: 0 to 100%
Parameter [26]: TORQUE LB-FT or NM
Definition:
Indicates the amount of torque available at the engine flywheel. Negative torque values will be displayed
with a minus sign in front of the value.
Typical Range: -9999 to 9999 LB-FT / -9999 to 9999 NM
Parameter [27]: ECM VOLTS
Definition:
Indicates the battery voltage available to the ECM
Typical Range: 0.0 to 32.0 Volts
H-260
|