TM 9-2320-360-20-1
Table 2-1. Preventive Maintenance Checks and Services (Cont)
ITEM TO BE
NOT FULLY
ITEM
INTERVAL
CHECKED OR
PROCEDURE
MISSION
NO.
SERVICED
CAPABLE IF:
28
Annually
TRANSMISSION
WARNING
(cont)
(CONT)
Compressed air for cleaning purposes will
not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal prot-
ective equipment (goggles/ shield, gloves,
etc.).
(3) Dry transmission breather (2) with
compressed air.
(4) Check inside transmission breather(2)
for contamination. Ensure cap moves in
and out freely.
WARNING
Pipe thread sealing compound may burn or
give off harmful vapors. It is harmful to skin
and clothing. To avoid Injury or death, keep
away from open flame and use In well-vent-
ilated area. If pipe thread sealing compound
gets on skin or clothing, wash Immediately
with soap and water.
CAUTION
Use pipe thread sealing compound sparingly
only on pipe threads. Do not apply com-
pound to hose connections. Failure to
comply may result in component failure.
(5) Coat threads of breather (2) with pipe
thread sealing compound.
(6) Install breather (2) in reducer (3).
2-59
|