TM 9-2320-356-BD
5.
Record the BDAR action taken.
When the mission is completed, as soon as
practicable,
repair using standard maintenance procedures.
Option 4:
High-Pressure Hose Repair (Same Size Hose Ends).
Procedural Steps:
1.
Use tape and wrap each end of hose to be cut. Cut section of hose to length
required.
Be sure each end is squarely cut.
2.
Spread a light coat of sealing compound on threads of one end of adapter.
3.
Install end with sealing compound into hose. Secure with clamps.
4.
Repeat steps 2 and 3 for other
5.
Record the BDAR action taken.
practicable,
repair using standard
end of hose.
When the mission is completed, as soon as
maintenance procedures.
Option 5:
High-Pressure Hose Repair (Different Size Line Ends).
Procedural Steps:
1.
Use tape and wrap each end of hose to be cut.
Cut section of hose to length
reauired.
Be sure
2.
Spread a light
3.
Install end of
each end is squarely cut.
coat of sealing compound on threads of one end of reducer.
reducer with sealing compound into hose.
Secure with clamp.
3-29
|