TM 9-2320-356-BD
Procedural Steps:
1.
Disconnect power at negative battery terminal.
2.
Gain access to engine starter; remove if necessary.
3.
Remove solenoid from starter.
4.
Rotate solenoid plunger shaft 180 degrees.
5.
Install solenoid on starter.
6.
Install starter, if removed.
7.
Connect power.
8. Test starter operation.
9.
Record the BDAR action taken.
When the mission is completed, as soon as
practicable, repair using standard maintenance procedures.
8-18
|