TM 9-2320-356-BD
6.
Insert the core into the brush plate and position the old brush wires under the
retaining springs to ensure electrical continuity.
7.
Seat the brushes:
a.
Cut a strip of sandpaper slightly wider than the commutator surface.
b.
Tape the sandpaper strip over the commutator.
c.
Install the brush plate.
d.
Rotate the armature in the normal direction of rotation until the carbon
core face conforms to the armature surface curvature.
e.
Remove sandpaper and blow out dust and sand.
8.
Assemble motor/alternator and test operation.
9.
Install motor/alternator.
10. Record BDAR action taken.
When the mission is completed, as soon as practicable,
repair using standard maintenance procedures.
8-17.
STARTER SOLENOID DEFECTIVE (DELCO-REMY ONLY)
General Information:
With uneven wear of the solenoid plunger shaft, a lip will form on one side of the
shaft and the engine starter will not engage.
Temporary repair can be made by
removing solenoid and rotating solenoid plunger shaft 180 degrees.
Limitations:
o Shorter starter solenoid life
Personnel/Time Required:
o 1 - 2 soldiers
o 30 - 60 minutes
Materials/Tools:
o None
8-17
|