TM 9-2320-312-24-2
Troubleshooting Section
If the parameter "Secondary Fuel Tank Size" is not
i01638698
programmed and a diagnostic code is active for the
0091-13 Throttle Sensor
secondary fuel level sensor, the ECM will broadcast
an error code over the J1939 data link. The ECM
will also broadcast the fuel level as 0 over the ATA
data link.
SMCS Code: 1913-524
Service Tool Display or Lamps Caterpillar
Conditions Which Generate This Code:
Electronic Technician (ET) will display "DIAG" next
to "Primary Fuel Level" on the status screen while
The duty cycle for the Accelerator Pedal Position
the diagnostic code is active.
Sensor signal is less than 5 percent or more than
95 percent.
Perform the following diagnostic procedure: "Fuel
Level Sensor Circuit - Test"
System Response:
Results:
Electronic System Response The ECM returns the
engine to low idle when the problem is detected.
OK STOP.
Service Tool Display or Lamps Caterpillar
Electronic Technician (ET) will display "0%" and
i01616821
"DIAG" next to "Throttle Position" on the status
0096-04 Primary Fuel Level
screen while the diagnostic code is active.
Sensor Short Circuit (44)
Engine Response The engine will remain at low
idle while the diagnostic code is active.
SMCS Code: 1408-081; 7483-038-NX
Troubleshooting:
Conditions Which Generate This Code:
Perform the following diagnostic procedure:
This diagnostic code is used only by GMT-560
"Accelerator Pedal (Throttle) Position Sensor Circuit
applications.
- Test"
The Primary Fuel Level signal voltage is below the
Results:
acceptable range for more than 10 seconds.
OK STOP.
System Response:
Electronic System Response If the parameter
i01616081
"Secondary Fuel Tank Size" is programmed and a
0096-03 Primary Fuel Level
diagnostic code for the secondary fuel level sensor
Sensor Open Circuit (44)
is not active, the ECM will use the secondary fuel
level sensor to determine the fuel level.
SMCS Code: 1408-081; 7483-038-NS
If the parameter "Secondary Fuel Tank Size" is not
programmed and a diagnostic code is active for the
Conditions Which Generate This Code:
secondary fuel level sensor, the ECM will broadcast
an error code over the J1939 data link. The ECM
This diagnostic code is used only by GMT-560
will also broadcast the fuel level as 0 over the ATA
applications.
data link.
The Primary Fuel Level signal voltage is above the
Service Tool Display or Lamps Caterpillar
acceptable range for more than 10 seconds.
Electronic Technician (ET) will display "DIAG" next
to "Primary Fuel Level" on the status screen while
System Response:
the diagnostic code is active.
Electronic System Response If the parameter
Perform the following diagnostic procedure: "Fuel
"Secondary Fuel Tank Size" is programmed and a
Level Sensor Circuit - Test"
diagnostic code for the secondary fuel level sensor
is not active, the ECM will use the secondary fuel
Results:
level sensor to determine the fuel level.
OK STOP.