Click here to make tpub.com your Home Page

Page Title: Maintenance Parameters
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-312-24-2
Troubleshooting Section
This switch input is required for some transmission
Table 101
styles. A switch can be wired to this input or a
Manual Hours
J1939 message may be used as an input.
Minimum
Maximum
Default
100
750
250
Table 98
"PM1 Engine Oil Capacity (Automatic
Alternative
Default
Maintenance Indicator Mode)"
"J1939 Body Controller"
"J1/P1:22"
"J1939 Cab Controller"
The "PM 1 Interval" can be determined by the
"J1939 Instrument Cluster"
ECM. The ECM bases the "PM 1 Interval" on
fuel usage. This parameter ("PM 1 Interval") must
be programmed only when the Maintenance
i01727522
Indicator Mode is programmed to an Automatic
Mode (Distance or Hours). Capacity of the sump
Maintenance Parameters
influences the maintenance interval.
SMCS Code: 1901
Table 102
Manufacturer
Minimum
Maximum
Default
"Maintenance Indicator Mode"
21 L
GM
19 L (20 qt)
57 L (60 qt)
The ECM records data that is related to the
(22 qt)
vehicle's maintenance. If "Distance" is selected,
31 L
all maintenance indications on the service tool will
Other
19 L (20 qt)
57 L (60 qt)
(33 qt)
be displayed in distance. Typical maintenance
indications are "PM 1", "PM 2" and the "Coolant
Flush/Fill".
OCT01 and newer Personality Modules.
Table 103
If "Hour" is selected, all maintenance indications
on the service tool will be displayed in Hours.
Manufacturer
Minimum
Maximum
Default
Typical maintenance indications are "PM 1", "PM
/ Model
2" and the "Coolant Flush/Fill". The ECM provides
21 L
"PM 1" maintenance interval and last maintenance
GM 530/540
19 L (20 qt)
57 L (60 qt)
(22 qt)
information.
GMT-560
19 L (20 qt)
57 L (60 qt)
28 L
Table 99
(30 qt)
Alternative
Default
31 L
Other
19 L (20 qt)
57 L (60 qt)
(33 qt)
Manual Distance
Manual Hours
OFF
Automatic Distance
Automatic Hours
i01728725
Output Selections
Note: When the "Truck Manufacturer" parameter is
programmed to "GMT-560", "Automatic Distance" is
SMCS Code: 1901
the default setting.
"Output #9"
"PM 1 Interval (Manual Maintenance Indicator
Mode"
OCT98 through JUN01 Personality Modules.
The "PM 1 Interval" allows a maintenance interval
"Output #9" can be used to connect a fast idle lamp
("PM 1") to be specified by the user. This parameter
or a wait to start lamp.
("PM 1 Interval") must be programmed only when
the Maintenance Indicator Mode is programmed to
If "Output #9" is programmed to "Fast Idle Lamp",
a Manual Mode (Distance or Hours).
the output will turn on when fast idle operation
is active. This requires the "Fast Idle RPM #1"
Table 100
parameter to be programmed to a value above low
Manual Distance
idle and a momentary switch to be installed on
input 18.
Minimum
Maximum
Default
8047 km
56327 km
24140 km
(5000 miles)
(35000 miles)
(15000 miles)

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business