TM 9-2320-312-24-2
Troubleshooting Section
"PTO Shutdown Time"
Table 36
Alternative
Default
The "PTO Shutdown Time" is the time (minutes) of
"Low Idle", "TEL" and
engine operation with the PTO on/off circuit ON and
"TEL"
"PTO TEL"
no vehicle speed before shutting down. The timer
will only count with no vehicle speed and the PTO
on/off circuit turned on. The PTO shutdown timer will
"PTO Kickout Vehicle Speed Limit "
not begin counting if the engine is in Cold Mode.
This parameter requires the "PTO Configuration"
This is the maximum vehicle speed for setting or
to be programmed to "Cab Switches", "Remote
maintaining a set engine rpm in PTO mode. PTO
Switches", or "Remote Throttle" for the timer to
Mode is entered if the PTO on/off switch is on. (This
function.
uses input 1.) If the vehicle speed signal exceeds
this value, the engine will not maintain the set
Note: This feature does not shut down the vehicle's
engine rpm.
power. The ECM and the vehicle remain powered.
Table 37
Table 39
Minimum
Maximum
Default
Manufacturer
Range
Default
/ Model
204 km/h
2 km/h (1 mph)
2 km/h (1 mph)
(127 mph)
1440 minutes
GM 530/540
3 minutes
GMT-560
to
0 minutes
"Torque Limit"
1440 minutes
Other
"PTO Activates Cooling Fan"
This parameter requires the use of the ECM cooling
fan circuit. When this parameter is programmed
to "Continuous", the ECM will signal the cooling
fan to run continuously when the PTO on/off circuit
is on. The cooling fan runs continuously in order
to reduce changes in the load while the engine is
being used for dedicated PTO applications. When
this parameter is programmed to "Normal", the PTO
on/off circuit does not affect the cooling fan. In this
mode, the operation of the fan is based on coolant
temperature, inlet air temperature or air conditioning
g00628600
Illustration 15
high head pressure. The "PTO Configuration"
must be programmed to "Cab Switches", "Remote
Operation of torque limit
Switches", or "Remote Throttle" before this
(1) Programmed torque limit
parameter can be programmed. The "Fan Control
Type" must be programmed to "On/Off".
The parameter for the "Torque Limit" defines the
maximum torque output of the engine during
Table 40
dedicated PTO operation. This parameter provides
temporary protection of equipment. The "Torque
Alternate
Default
Limit" of the engine is active when the circuit for the
"Continuous"
"Normal"
torque limit switch is on. The maximum value is the
rated torque of the engine. The "Torque Limit" is
programmable to Nm (lb ft) of torque. Programming
"Maximum PTO Enable Speed"
a value higher than the rated torque is limited by the
ECM to rated torque. The torque limit is indicated
This parameter specifies the maximum engine
by the dashed line in Illustration 15.
speed for the engagement of the PTO mode. The
PTO mode will engage when the engine rpm is
Table 38
equal to the programmed limit or less than the
Minimum
Maximum
Default
programmed limit.
135 Nm
2712 Nm
2712 Nm
(2000 lb ft)
(100 lb ft)
(2000 lb ft)