TM 9-2320-312-24-2
Troubleshooting Section
(Table 6, contd)
Customer Specified Parameter Table
Parameter
Default
Available Range or Options
700 to 800 rpm
700 rpm
Low Idle Engine RPM
Idle Quality Calibration
Decrease 1, 2, 3, or 4
Nominal
Increase 1, 2, 3, or 4, Nominal
Transmission Style
GM: Universal
Manual Option 1
Manual Option 2
Automatic Option 1
GM 30/540: Universal
Automatic Option 2
GMT-560: Manual Option 2
Automatic Option 3
Other: ManualOption 1
Automatic Option 4
AT/MT/HT Option 1
AT/MT/HT Option 2
AT/MT/HT Option 3
AT/MT/HT Option 4
AT/MT/HT Part Throttle Shift Speed
Low and Medium
High
7.375
1.25
Fan Pulley Ratio
Governor Type
Min/Max
Full Range
Timer Parameters
Idle Shutdown Time
3 to 1440 minutes
0 minutes
Allow Idle Shutdown Override
YES
YES
NO
A/C Switch Fan-On Time
0 to 600 seconds
0 seconds
Full Feature Only
Fan with Engine Brake On
YES or NO
NO
Full Feature Only
Exhaust Brake Configuration
GM 530/540: Exhaust Brake Only
None, Warm Up Only, Exhaust
GMT-560: None
Brake & Warm Up
Other: Exhaust Brake Only
700 rpm to 1400 rpm
1000 rpm
Warm Up Mode Idle Speed
Smart Idle Parameters
Battery Monitor & Engine Control
GM 530/540: 0 Volts
0 Volts to 25.5 Volts
Voltage
GMT-560: 11.5 Volts
Other: 0 Volts
1000 rpm
Battery Monitor Low Idle Speed Monitor
700 rpm to TEL
Engine Monitoring Parameters
Engine Monitoring Mode
GM: OFF,DERATE
WARNING
Other: OFF,DERATE,
SHUTDOWN
Engine Monitoring Mode
GM 530/540: WARNING,DERATE
GM: WARNING
OCT01 and newer Personality Modules
GMT- 560 & Other: WARNING,DERATE
Other: DERATE
SHUTDOWN
Engine Monitoring Lamps (GM only)
High Coolant Temp Warning Lamp
Warning Lamp
or Warning Lamp
Coolant Level Sensor
GM: NA
4-pin
Other: NO
(continued)
|