TM 9-2320-312-24-2
Testing and Adjusting Section
Table 28
DAYCO Supplied Belts Only
Belt Tension
Belt Tension
Size of Belt
"Initial"
"Used"(4)
0.380 (V-Belt)
623 22 N (140 5 lb)
245 - 534 N (100 5 lb)
0.440 (V-Belt)
667 22 N (150 5 lb)
245 - 534 N (100 5 lb)
0.500 (V-Belt)
712 22 N (160 5 lb)
245 - 534 N (100 5 lb)
0.600 (V-Belt)
779 22 N (175 5 lb)
245 - 534 N (100 5 lb)
0.660 (V-Belt)
890 22 N (200 5 lb)
245 - 534 N (100 5 lb)
0.790 (V-Belt)
890 22 N (200 5 lb)
245 - 534 N (100 5 lb)
4 - RIB PVK
623 22 N (140 5 lb)
267 - 445 N (90 5 lb)
5 - RIB PVK
779 22 N (175 5 lb)
334 - 556 N (100 5 lb)
6 - RIB PVK
934 22 N (210 5 lb)
400 - 667 N (130 5 lb)
8 - RIB PVK
1157 22 N (260 5 lb)
534 - 890 N (180 5 lb)
10 - RIB PVK
1557 22 N (350 5 lb)
667 - 1112 N (230 5 lb)
12 - RIB PVK
1869 22 N (420 5 lb)
800 - 1335 N (270 5 lb)
15 - RIB PVK
2336 22 N (525 5 lb)
1000 - 1669 N (350 5 lb)
(4)
If a belt falls below the "Used" belt tension, the belt should be tightened again to the "Initial" belt tension.
Test Tools For The Charging
i01852470
Charging System - Test
System
Table 29
SMCS Code: 1406-081
Tools Needed
The condition of charge in the battery at each
Part
regular inspection will show if the charging system
Part Name
Quantity
Number
is operating correctly. An adjustment is necessary
when the battery is constantly in a low condition
1
8T-0900
Ammeter
of charge or a large amount of water is needed.
6V-7070 Digital Multimeter
A large amount of water would be more than one
1
or
or
ounce of water per a cell per a week or per every
146-4080 Digital Multimeter
100 service hours.
When it is possible, make a test of the charging unit
8T-0900 Ammeter
and voltage regulator on the engine, and use wiring
and components that are a permanent part of the
system. Off-engine testing or bench testing will give
a test of the charging unit and voltage regulator
operation. This testing will give an indication of
needed repair. After repairs are made, perform
a test in order to prove that the units have been
repaired to the original condition of operation.
g00296441
Illustration 91
8T-0900 Ammeter
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |