Click here to make tpub.com your Home Page

Page Title: Water Pump - Test
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-312-24-2
Testing and Adjusting Section
2. Heat water in a pan until the temperature of the
water is equal to the fully open temperature
of the water temperature regulator. Refer to
Specifications, "Water Temperature Regulator"
for the fully open temperature of the water
temperature regulator. Stir the water in the pan.
This will distribute the temperature throughout
the pan.
3. Hang the water temperature regulator in the pan
of water. The water temperature regulator must
be below the surface of the water. The water
temperature regulator must be away from the
sides and the bottom of the pan.
g00296313
Illustration 77
4. Keep the water at the correct temperature for
ten minutes.
Pressure test ports for the water pump (Typical example)
(1) Port (alternate heater supply)
5. After ten minutes, remove the water temperature
(2) Port (engine diagnosis)
(3) Port (heater return line)
regulator. Immediately measure the opening
of the water temperature regulator. Refer to
Specifications, "Water Temperature Regulator"
for the minimum opening distance of the
water temperature regulator at the fully open
Making contact with a running engine can cause
temperature.
burns from hot parts and can cause injury from
rotating parts.
If the distance is less than the amount listed in the
manual, replace the water temperature regulator.
When working on an engine that is running, avoid
contact with hot parts and rotating parts.
i01849228
The pressure rise is the difference between inlet
Water Pump - Test
pressure and outlet pressure. The pressure rise
indicates if the water pump operates correctly. Port
SMCS Code: 1361-081
(1) and Port (2) represent the water pump outlet
pressure. Port (3) represents the water pump inlet
Table 23
pressure.
Required Tools
To measure the pressure rise, compare inlet
Part
Part Name
Quantity
pressure with outlet pressure. Calculate the
Number
difference between the pressure of the inlet port
1
6V-7775
Air Pressure Gauge
and the outlet ports. The pressure rise must add
up to a minimum of 80 kPa (12 psi) under both of
8J-7844
1
Adapter Fitting
the following conditions:
1
3K-0360
O-Ring Seal
The engine is at operating temperature.
5P-2725
Probe Seal Adapter
1
1
164-2192
Pressure Probe(1)
The engine operates at full load condition.
1
5P-4487
Adapter
5P-2720
1
Probe Adapter
(1)
If port (1) is used, two tools are required.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business