24
TM 9-2320-312-24-2
Systems Operation Section
Operation of the Injection Actuation
Pressure Control Valve
g00295335
Illustration 11
Injection actuation pressure control valve
(9) Poppet
(5) Armature
(1)
Drain port
(10) Push pin
(6) Valve spool
(2)
Valve body
(11) Solenoid
(7) Spool spring
(3)
Control orifice
(8) Reduced pressure oil
(4)
Spool chamber
Push pin (10)
The IAP Control Valve is an electrically controlled
pilot operated pressure control valve. The Injection
Solenoid (11)
Actuation Pressure Control Valve is used in order to
maintain selected actuation system pressure. The
selected actuation system pressure is maintained
The IAP Control Valve operates by using a
regardless of engine speed, pump flow, and
variable electrical current from the ECM in order
variable oil demand of the unit injectors. The IAP
to create a magnetic field in the solenoid (11).
Control Valve consists of six basic components:
This magnetic field acts on armature (5) and the
magnetic field generates a mechanical force. This
Armature (5)
mechanical force pushes armature (5) to the left.
The mechanical force travels through push pin (10)
Valve spool (6)
to poppet (9).
Spool spring (7)
Poppet (9)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |