TM 9-2320-312-24-1
HYDRAULIC SYSTEM VALVES REPLACEMENT - CONTINUED
0128 00
FLOW CONTROL VALVE INSTALLATION - CONTINUED
NOTE
Use strip caulk at cable guide to assist in keeping spacers in position as they are installed.
4.
Install two spacers (32) and two halves of cable guide (30) to control cable (26) and control valve (19) with two screws
(31).
NOTE
Replacement cable guide comes with new lockwashers.
5.
Install two screws (29), lockwashers (28), and nuts (27) to end of cable guide (30).
31
30
27,28,29
19
26
32 (USE STRIP CAULK)
6.
Connect load sensing gauge hose (25) to straight fitting (24).
7.
Connect hydraulic hose (21) to elbow (20).
8.
Connect three hydraulic hoses (23) to straight fittings (22).