TM 9-2320-312-24-1
HYDRAULIC SYSTEM VALVES REPLACEMENT - CONTINUED
0128 00
FLOW CONTROL VALVE INSTALLATION
NOTE
Ensure new preformed packings, coated with hydraulic fluid, are used on hydraulic fittings prior to installa-
tion.
1.
Install three straight fittings (22), elbow (20), and straight fitting (24) to control valve (19).
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Failure to follow this warning may result in injury to personnel.
2.
Install control valve (19) to crossmember (35) with three bolts (37) and nuts (36).
3.
Connect control cable (26) to control valve (19) with pin (34) and wire clip (33).
33
19
26
34
0128 00-9
|