TM 9-2320-312-24-1
HYDRAULIC SYSTEM VALVES REPLACEMENT - CONTINUED
0128 00
CYLINDER LOCKING VALVE INSTALLATION - CONTINUED
NOTE
Ensure new preformed packings, coated with hydraulic fluid, are used on hydraulic fittings prior to installa-
tion.
3.
Install tee (9) to locking valve (2).
4.
Install locking valve (2) to mounting bracket (4) with two flatwashers (7), bolts (6), and new locknuts (5).
5.
At left side of locking valve (2), connect hydraulic hose (8).
6.
At right side of locking valve (2), connect hydraulic hose (3).
7.
Connect two hydraulic hoses (1) to tee (9).
1
2
3
4
5,6,7
9
8
1
8.
Fill hydraulic reservoir with hydraulic fluid (WP 0129 00).
9.
Install rear platform grating (WP 0039 00).