TM 9-2320-312-24-1
INLET AIR HEATER 120A CIRCUIT BREAKER REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Materials/Parts
Insulating varnish, electrical dielectric (Item 34,
Unit
MAC Reference
Strap, tiedown (Item 57, WP 0165 00)
Tag, marker (Item 58, WP 0165 00)
Group 170
Nut, lock (P/N 21NE048) (2)
RPSTL Reference
Equipment Condition
Group 170, Figure 11
Cab tilted (TM 9-2320-312-10)
Tools and Special Tools
Battery disconnect switch in OFF position
Transmission access cover removed (WP 0039 00)
Tool kit, general mechanic's (Item 35, WP 0166 00)
REMOVAL
NOTE
Tag cables to ensure correct installation.
Remove and discard tiedown straps as necessary. Use new tiedown straps on installation.
Terminals are coated with insulating varnish and paint. Remove insulating varnish and paint to access
terminals.
1.
Remove two nuts (6) and starwashers (7) and disconnect two cables (5) from circuit breaker (4).
2.
Remove two locknuts (2), screws (3), and circuit breaker (4) from crossmember (1). Discard locknuts.
1
2,3
4
6,7
5
|