TM 9-2320-312-24-1
STOWAGE COMPARTMENT REPLACEMENT - CONTINUED
0085 00
REMOVAL
1.
Remove two locknuts (5), clamps (7), and release three air reservoir cable pulls (8) from welded studs (6) on mounting
bracket (2). Discard locknuts.
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Failure to follow this warning may result in injury to personnel.
2.
Remove four nuts (12), bolts (13), and two mounting brackets (2 and 9) with stowage compartment (1) from right frame
rail (14).
1
12,13
14
2
1
3,4
5,6
7
8
9
10
11
3.
Remove two nuts (3), bolts (4) and two mounting brackets (2 and 9) from stowage compartment (1).
4.
If damaged, remove ten rivets (11) and hinge (10). Discard rivets.
5.
If damaged, remove weatherseal (15). Retain removed weatherseal to use as a template to cut correct length of new
weatherseal.