LOAD SENSING GAUGE AND HOSES REPLACEMENT - CONTINUED
0084 00
REMOVAL - CONTINUED
5.
Trace hose (5) to bulkhead fitting (7) on right side, inside cab.
6.
Disconnect hose (5) from elbow (8).
7.
Remove elbow (8) from bulkhead fitting (7).
5
8
7
NOTE
Perform steps 8 through 14 to remove hose from between underside of cab and flow control valve, on right
side of crossmember directly behind cab.
8.
Tilt cab (TM 9-2320-312-10).
9.
Disconnect hose (12) from elbow (11).
10.
Remove elbow (11) from bulkhead fitting (7).
11.
Remove nut (10), washer (9), and bulkhead fitting (7) from cab.
11
12
10
9
7
7
0084 00-4