TM 9-2320-312-10
Table 1. Preventive Maintenance Checks and
Services (PMCS) for M878A2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
8
Before
Fire Extin-
a. Check for missing or damaged fire a. Fire extinguisher is missing or dam-
extinguisher.
aged.
guisher
b. Check gauge for proper pressure. b. Pressure gauge needle is in red area.
Gauge needle should be in green
area on gauge.
c. Check for broken or missing seal.
c. Seal is broken or missing.
SEAL
GAUGE
CAUTION
9
Before
Engine
Startup
After engine is started, all warning lights should go out in approximately
15 seconds. If warning lights do not go out, shut down engine and investi-
gate cause. Failure to follow this caution may damage engine.
a. Start engine (WP 0005 00). Verify a. Engine will not start. LOW AIR
that LOW AIR warning light and
warning light and buzzer do not
buzzer come on.
come on.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |