TM 9-2320-312-10
OPERATION UNDER UNUSUAL CONDITIONS - CONTINUED
0006 00
SLAVE START TRACTOR - CONTINUED
1.
Ensure battery disconnect switch is in OFF position on "dead" vehicle.
2.
Connect NATO slave cable to receptacle on "dead" vehicle.
NATO SLAVE
RECEPTACLE
3.
Connect other end of NATO slave cable to receptacle on "live" vehicle.
4.
Start engine of "live" vehicle and run at 1000 rpm.
5.
Place battery disconnect switch and ignition switch on "dead" vehicle to ON position.
6.
Allow "live" vehicle to run for 2-3 minutes to charge capicator(s) on "dead" vehicle.
7.
Place ignition switch and then battery disconnect switch on "dead" vehicle to OFF position.
8.
Shut down "live" vehicle and disconnect NATO slave cable from both vehicles.
9.
Place battery disconnect switch on "dead" vehicle in ON position.
10. Turn ignition switch to START position and start vehicle.
NOTE
With engine at idle speed, check instrument panel voltmeter to ensure voltmeter indicator is in GREEN area.
If voltmeter indicator is NOT in GREEN area, shut down engine and continue slave starting steps.
11. Connect NATO slave cable to receptacle on "dead" vehicle.
12. Connect other end of NATO slave cable to receptacle on "live" vehicle.
13. Start engine of "live" vehicle and run at 1000 rpm.
14. Place battery disconnect switch and ignition switch on "dead" vehicle to ON position.
15. Allow "live" vehicle to run for 15 minutes to charge vehicle batteries and capacitor(s).
16. Place ignition switch and then battery disconnect switch on "dead" vehicle to OFF position.