TM 9-2320-304-14&P
5-121
Direct Support and General Support Maintenance (Cont)
WARNING
The LHS hydraulic system operates at oil pressures up to 1,725 psi (11 894 kPa). Never
disconnect any hydraulic line or fitting without first dropping pressure to zero. Failure
to comply may result in serious injury or death to personnel.
NOTE
·
Tag and mark all hoses prior to removal.
·
Cap and plug hydraulic hoses and tubes after removal.
·
Remove cable ties as required.
(11) Remove two screws (11), lockwashers (12), washers (13), cover plates (14), and four clamps (15).
(12) Remove screw (11), lockwasher (16), cover plate (14), two clamps (15), hose 2891 (17), and hose
2881 (18) from main frame (5).
NOTE
Step (13) applies to tubes on left side only.
(13) Remove adapter (19), preformed
packing (20), spacer (21), compression
ring (22), and nut (23) from tube (24).
Discard preformed packing.
|