TM 9-2320-304-14&P
4-162
Organizational Maintenance Instructions (Cont)
4-31. HYDRAULIC SELECTOR SWITCH REPLACEMENT (CONT).
NOTE
Tag and mark wires prior to removal.
(6) Loosen eleven captive screws (10) and
remove wires 1724 (11), 1487 (12), 1483
(13), 1481 (14), 1480 (15), 1486 (16),
1482 (17), 1484 (18), and 1485 (19) from
hydraulic selector switch (8).
(7) Remove two jumperwires (20) from
hydraulic selector switch (8).
(8) Loosen twelve captive screws (21) and
remove wires 1488 (22), 1489 (23), and
1490 (24).
(9) Remove nine jumperwires (25) from
hydraulic selector switch (8).
b. Installation.
(1) Install three wires 1488 (1), 1489 (2),
and 1490 (3) in hydraulic selector
switch (4) with three captive screws (5).
(2) Install nine jumperwires (6) in
hydraulic selector switch (4) with nine
captive screws (5).
|