Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-142.13
Organizational Maintenance Instructions (Cont)
Table 4-3.1. Container Handling Unit (CHU) Troubleshooting (CONT)
CONTAINER HANDLING UNIT (CHU) (CONT)
3. HOOK ARM EXTENDS TOO FAR (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 7. Remove relay R54 and check for continuity between wire 1435 at relay R55, terminal 2 and
relay R54, terminal 2.
If there is no continuity, repair wire 1435.
Change 1
|