Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-142.12
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3.1. Container Handling Unit (CHU) Troubleshooting (CONT)
CONTAINER HANDLING UNIT (CHU) (CONT)
3. HOOK ARM EXTENDS TOO FAR (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 6. Remove relay T55 and check for continuity between wire 1495 at connector MC185A,
terminal F and relay R55, terminal 2.
If there is no continuity, replace CHU control box wiring (Para 4-34.2).
Change 1
|