Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-131
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
16. LHS DOES NOT LOAD IN AUTO MODE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 7. Check for 22 to 28 Vdc at LHS junction box terminal 4 with main frame down and 0 Vdc
measured with main frame up.
If there are 22 to 28 Vdc, replace proximity switch (Para 4-37).
|