Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-47
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
4. LHS OVER LOAD INDICATOR DOES NOT GO OUT (CONT).
WARNING
Keep clear of equipment when equipment is being raised or lowered. Equipment may fall
and cause serious injury or death to personnel.
Step 2. Check operation of LHS OVER LOAD indicator.
If LHS OVER LOAD indicator operates and fails to go out, replace LHS distribution
box (Para 4-34).
Step 3. Check operation of LHS OVER LOAD indicator.
If LHS OVER LOAD indicator operates and fails to go out, fault is not corrected.
Notify DS Maintenance.
|