Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-45
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
3. LHS OVER LOAD INDICATOR DOES NOT OPERATE (CONT).
WARNING
·
Keep clear of equipment when equipment is being raised or lowered. Equipment
may fall and cause serious injury or death to personnel.
·
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact
positive electrical circuits, a direct short may result. Damage to equipment and
injury or death to personnel may occur.
Step 9. Check for continuity on wire 1435 at LHS OVER LOAD indicator connector and chassis
ground.
If there is no continuity, repair wire 1435 or notify DS Maintenance.
Step 10. Check LHS OVER LOAD indicator operation.
If LHS OVER LOAD indicator does not operate, fault not corrected. Notify DS
Maintenance.
|