TM 9-2320-304-14&P 5-265 Direct Support and General Support Maintenance (Cont) NOTE · Install cable ties as required. · Connector MC189 does not connect to anything. MC189 is removed with the CHU wiring harness. (210)   Position CHU wire harness (146) and two MC190 connectors (215) along inside of left-side frame rail (4). (211)   Position CHU wiring harness (146) with MC188 connector (216) along inside of compression frame (192) with existing wires. (212)   Position CHU wiring harness (146) with MC185 connector (217) along inside of main frame (178) with existing wires. (213)   Connect two MC190 connectors (215) to right and left rear lock limit switch (142). (214)   Connect MC188 connector (216) to CHU hook arm up arm proximity switch (190). (215)   Connect MC186 connector (217) to CHU main frame up proximity switch (195). Change 1