TM 9-2320-304-14&P
5-260
Direct Support and General Support Maintenance (Cont)
5-43. CONTAINER HANDLING UNIT (CHU) KIT INSTALLATION (CONT).
(185) Position proximity switch mounting
plate (195) with two clamps on main
frame (178) as shown.
(186) Mark a line around proximity switch
mounting plate (195) on main
frame (178).
(187) Remove two clamps and proximity
switch mounting plate (195) from main
frame (178).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
NOTE
Mix epoxy according to directions on
package.
(188) Mix epoxy supplied with CHU kit and
apply to proximity switch mounting
plate (195) and main frame (178).
NOTE
Epoxy takes approximately 15 minutes to
cure.
(189) Clamp proximity switch mounting
plate (195) to main frame (178) until
cured.
(190) Remove clamps from main frame (178).
(191) Prime and paint area as necessary
(TM 43-0139).
Change 1
|