TM 9-2320-303-24-2
AIR CONDITIONER HOSE REPLACEMENT - CONTINUED
0305 00
REMOVAL
1.
The following air conditioning system hoses can be replaced:
a.
Compressor-to-tube assembly on firewall
b.
Compressor-to-condenser
c.
Receiver-dryer-to-tube assembly on firewall
d.
Receiver-dryer-to-expansion valve
e.
Tube assembly (on firewall)-to-expansion valve (2 places)
2.
Remove insulation tape from each hose connection.
NOTE
DO NOT disconnect or connect refrigerant fittings using only one wrench. Hold one fitting in place using a
wrench and turn other fitting with a second wrench.
3.
Disconnect each end of hose connection.
CAUTION
Water and dirt can damage refrigerant system. Five minutes of not being capped is the limit for any hose or
component. DO NOT blow shop air through refrigerant hoses. Shop air is wet (humid).
4.
Cap each opening where hose was disconnected.
5.
At firewall, remove two screws (2), washers (3), tube assembly (1), and gasket (4). Discard gasket.
1
4
3
2
INSTALLATION
1.
Install gasket (4) on tube assembly (1) and tube assembly on firewall.
2.
Install two washers (3) and screws (2).
0305 00-2
|