TM 9-2320-303-24-2
HEATING, VENTILATION, AIR CONDITIONING (HVAC) UNIT REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Materials/Parts - Continued
Oil, refrigerant (Item 34, WP 0312 00)
Direct Support
Rags, wiping (Item 39, WP 0312 00)
Tools and Special Tools
Tags, marker (Item 42, WP 0312 00)
Tool kit, general mechanic's (Item 102, WP 0313
Tape, insulation (Item 46, WP 0312 00)
Personnel Required
Dispenser, sealant (Item 19, WP 0313 00)
Two
Gloves, protective (Item 27, WP 0313 00)
Goggles (Item 30, WP 0313 00)
References
Wrench, torque, 15-75 lb-ft (Item 110, WP 0313
WP 0218 00
Materials/Parts
Adhesive, loctite (Item 3, WP 0312 00)
Equipment Condition
Cap set (Item 8, WP 0312 00)
Cooling system drained (WP 0045 00)
Refrigerant recovered (WP 0297 00)
Compound, gasket forming (Item 14, WP 0312 00)
WARNING
Use care to prevent refrigerant from touching your skin or eyes. Liquid refrigerant, when exposed to
air, quickly evaporates and will freeze skin or eye tissue. Serious injury or blindness may result if
you come in contact with liquid refrigerant.
Refrigerant R-134a air conditioning systems should not be pressure tested or leak tested with com-
pressed air. Combustible mixtures of air and R-134a may form, resulting in a fire or explosion, which
could cause personnel injury or death.
|