TM 9-2320-303-24-2
TRANSMISSION OVERHAUL - CONTINUED
0248 00
ASSEMBLY - CONTINUED
Installation of Torque Converter Housing Module
1.
Position transmission with input end up. Install a new converter housing gasket (25) on main housing (24).
2.
Lower torque converter housing (22) onto main housing (24) while rotating PTO drive gear to align gear teeth with
charging pump.
3.
Install seven bolts (23) into inside of torque converter housing (22). Use of mechanical fingers or similar tool may be
required to insert and start bolts.
4.
Install remaining 18 bolts (23). Tighten all bolts to 55-65 lb-ft (74-88 Nm)
22
23
24
25