TRANSMISSION OVERHAUL - CONTINUED
0248 00
MODULE OVERHAUL - CONTINUED
Torque Converter Housing Module Disassembly
1.
Remove ten bolts (11), PTO cover (10), and gasket (9). Discard gasket.
2.
Remove 11 bolts (1) securing bearing retainer assembly (2) and PTO gear (12) assembly to converter housing (8).
3.
Remove seal rings (3 and 4) from bearing retainer (2). Discard seal rings.
4.
Remove bearing retainer oil seal (15) using tool (J24171-A). Discard oil seal.
5.
Inspect bushing (14) for damage or wear. Maximum allowable bushing ID is 3.511 in (89.19 mm). Remove if damaged
or worn.
6.
Remove oil pump drive hub (5) from PTO gear (12).
7.
Inspect oil pump drive hub (5) for excessive wear on drive tangs. Maximum allowable tang wear is 0.012 in (0.31 mm).
8.
Remove seal ring (7) from PTO gear (12).
9.
Inspect PTO gear bearings (6 and 13). If damaged, remove and discard.
1
2
3
4
15
14
5
8
6
7
13
12
9
10
11
0248 00-15
|