AIR CONDITIONER FAN CYCLING SWITCH REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Materials/Parts - Continued
Maintenance Level
Unit
Rags, wiping (Item 39, WP 0312 00)
Tools and Special Tools
References
Tool kit, general mechanic's (Item 102, WP 0313
TM 9-2320-303-10
Wrench, torque, 15-75 lb-ft (Item 110, WP 0313
Equipment Condition
Hood opened (TM 9-2320-303-10)
Materials/Parts
Master battery switch in OFF position (TM 9-2320-
Oil, refrigerant (Item 34, WP 0312 00)
303-10)
REMOVAL
1.
Disconnect harness connector (1) from fan cycling switch (4).
2.
Unscrew fan cycling switch (4) from coupling (3) on receiver-dryer (2). Remove and discard preformed packing.
1
2
4
3
INSTALLATION
1.
Lubricate new preformed packing with refrigerant oil and install over male threads of coupling (3) on receiver-dryer (2).
2.
Screw fan cycling switch (4) into coupling (3). Tighten switch to 20-25 lb-ft (27-34 Nm).
3.
Connect harness connector (1) to fan cycling switch (4).