TM 9-2320-303-24-1
SECONDARY AIR TANK AND FITTINGS - CONTINUED
0131 00
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.
NOTE
Perform steps 1 and 2 only if fittings have been removed from air tank.
Install automatic drain valve (WP 0133 00) if equipped.
1.
Coat pipe threads of new drain valve (29), new pressure protect valve (30), new bushing (25), new tee (22), new connec-
tor (21), new plug (27), new check valve (28), and four new elbows (23) with pipe sealant compound.
2.
Install drain valve (29), pressure protect valve (30), bushing (25), tee (22), connector (21), plug (27), check valve (28),
and four elbows (23) in new air tank (26).
3.
Install two brackets (10), two washers (14), two capscrews (15), two washers (9), and two new locknuts (8).
4.
Install two mounting brackets (11), two clamps (16), two washer (17), and two new locknuts (18).
5.
Install two brackets (1), two washers (5), and two new locknuts (4).
6.
Install cable (19), two washers (2), two capscrews (3), two washers (6), and two new locknuts (7).
7.
Install air tank (26), two screws (13), and two new locknuts (12).
8.
Connect hose (24) and four tubes (20) to air tank (26).
9.
Start vehicle and check for leaks (TM 9-2320-303-10).
END OF WORK PACKAGE
0131 00-3/(0131 00-4 blank)
|