TM 9-2320-303-24-1
SECONDARY AIR TANK AND FITTINGS - CONTINUED
0131 00
REMOVAL
NOTE
Tag all tubes prior to disconnecting to aid in connecting.
1.
Disconnect four tubes (20) and hose (24) from air tank (26).
2.
Remove two locknuts (12), two screws (13), and air tank (26). Discard locknuts.
3.
Remove two locknuts (7), two washers (6), two capscrews (3), and two washers (2) and set cable (19) aside. Discard
locknuts.
4.
Remove two locknuts (4), two washers (5), and two brackets (1). Discard locknuts.
5.
Remove two locknuts (18), two washers (17), two clamps (16), and two mounting brackets (11). Discard locknuts.
6.
Remove two locknuts (8), two washers (9), two capscrews (15), two washers (14), and two brackets (10). Discard lock-
nuts.
NOTE
Perform step 7 only if fittings or air tank are to be replaced.
Remove automatic drain valve (WP 0133 00) if equipped.
7.
Remove four elbows (23), check valve (28), plug (27), connector (21), tee (22), bushing (25), pressure protect valve
(30), and drain valve (29).
5
4
3
2
1 3
4 5
1
6
2
7
8
19
10
9
18
11
17
16
6
12,13
7 18
17
14
16
8
15
9
10
26
27
20
23 24
25
22
23 20
21
28
20
23
29
30
23
0131 00-2
|