Page Title: REMOVAL
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-303-24-1
THERMOSTAT AND HOUSING MAINTENANCE - CONTINUED
0047 00
REMOVAL
1.
Loosen and remove bypass hose clamp (4), radiator inlet hose clamp (10), and hose (9).
2.
Unscrew compressor coolant line (15) from fitting (8).
3.
Unscrew and remove two capscrews (2) and washers (1).
4.
Remove elbow (3) and gasket (5). Check elbow for cracks. Discard gasket.
5.
Unscrew and remove four capscrews (7) and washers (6).
6.
Tap thermostat housing (11) with a soft head hammer and remove. Check housing for cracks, damaged fittings, or stains
from leaks. Replace if necessary.
7.
Remove gasket (14), thermostat (13), and rubber seal (12). Discard gasket and rubber seal.
3
2
4
1
5
6
14
7
13
12
8
8
15 11
10
9
10
TESTING
1.
Check that at room temperature, thermostat (13) is closed. If thermostat does not work, replace it.
2.
Put thermostat (13) in hot water. When temperature reaches 185F (85C), thermostat should open.