|
|
TM 9-2320-303-24-1
Table 1. Standard Heater Circuit Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Heater Fan Does Not Operate In Any Speed - 6. Disconnect heater fan high If +12 VDC is present, go to step
Continued
relay from connector. Check 7. If no voltage is present, repair
for +12 VDC at connector 87. lead 98.
7. Check for continuity between If continuity is indicated, go to
connector 86 and ground for step 8. If no continuity is
both relays.
indicates, repair ground lead.
8. Disconnect heater fan power If +12 VDC is present, go to step
relay from connector. Check 9. If no voltage is present, repair
for +12 VDC at connector 85. lead 71AA.
9. Disconnect lead 98 from heater If +12 VDC is present, go to step
fan control. Check for +12 10. If no voltage is present,
disconnect heater fan power relay.
VDC at lead 98.
Check for continuity in lead 98. If
continuity is indicated, replace
heater fan power relay (WP 0072
repair lead 98.
10.Disconnect lead 98L from
If +12 VDC is present, go to step
heater fan control. Check for
11. If no voltage is present,
+12 VDC at heater fan control
replace heater fan control (WP
connector (D) with heater fan
control in high mode.
11.Disconnect heater fan high If +12 VDC is present, go to step
relay from connector. Check 12. If no voltage is present, repair
for +12 VDC at connector 85 lead 98L.
with heater fan control in high
mode.
12.Disconnect lead 98T from
If +12 VDC is present, go to step
heater fan motor. Check for
13. If no voltage is present,
+12 VDC at lead 98T with
disconnect heater fan high relay
heater fan control in high mode.
from connector. Check for
continuity in lead 98T between
connector 30 and heater fan
motor. If continuity is indicated,
replace heater fan high relay (WP
0072 00). If no continuity is
indicated, repair lead 98T.
13.Disconnect ground lead from
If continuity is indicated, replace
heater fan motor. Check for
heater fan motor (WP 0211 00). If
continuity between ground lead
no continuity is indicated, repair
and ground.
ground lead.
0010 00-39
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |