POWER TAKE-OFF (PTO) SOLENOID VALVE REPLACEMENT (M916A3, M917A2) - CONTINUED
0273 00
REMOVAL - CONTINUED
6.
Disconnect electrical connector (7).
NOTE
Tag wires prior to removal to aid in installation.
7.
Remove two screws (8) and disconnect two wires (9) from PTO solenoid valve (10).
8.
Remove PTO pressure switch (11) from PTO solenoid valve (10).
4
3
14
13
3
5
12
10 11
9
8
9
8
7
6
INSTALLATION
1.
Install PTO pressure switch (11) on PTO solenoid valve (10).
2.
Connect two wires (9) and install two screws (8) on PTO solenoid valve (10).
3.
Connect electrical connector (7).
4.
Install two tiedown straps (4).
5.
Connect air hose (6) to PTO (5) and PTO solenoid valve (10).
6.
Install PTO solenoid valve (10), connect ground wire (12), and install washer (13), washer (14), and two screws (3).
7.
Connect two air hoses (1).
8.
Connect hose assembly (2).
Install transmission tunnel access cover (WP 0268 00).
9.
END OF WORK PACKAGE