TM 9-2320-302-20-2
AIR TANK AUTOMATIC DRAIN VALVE REPLACEMENT (M915A3 NEW MODEL,
M916A3, M917A2) - CONTINUED
INSTALLATION
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive or
sealing compound contacts skin or clothing, wash immediately with soap and water.
4.
Apply pipe sealing compound to threads of adapter (2).
5.
Install adapter (2) on drain valve (1).
6.
Install drain valve (1) on air tank (3).
2
1
3
7.
Start vehicle and check air system (TM 9-2320-302-10).
END OF WORK PACKAGE