TM 9-2320-302-20-2
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0151 00
COMMERCIAL CONNECTOR REPAIR - CONTINUED
(7)
Push contact into grommet until a positive stop is felt (Figure 15). A slight tug will confirm that it is prop-
erly locked into place (Figure 16).
LOCKED POSITION
UNLOCKED POSITION
Figure 16. Locking Terminal into Connector.
c.
Removal. The appropriate size removal tool should be used when removing cables from connectors. The proper
removal tool size is listed in Table 1.
(1)
With rear insert toward you, snap appropriate size removal tool over cable of contact to be removed (Fig-
ure 17).
Figure 17. Removal Tool Position.