b.
Installation. Use the following instructions for terminal installation:
(1)
Insert terminal into locating hole of crimping tool using proper hole according to gage of cable to be used
(Figure 7).
J38706
OR EQUIVALENT
CABLE
SEAL
TERMINAL
Figure 7. Terminal Position.
(2)
Insert cable into terminal until stripped position is positioned in cable core wings, and seal and insulated
portion of cable are in insulation wings (Figure 8).
CABLE CORE
INSULATION WINGS
WINGS
BEFORE
AFTER
Figure 8. Cable and Terminal Position Before and After Crimping.