TM 9-2320-302-20-2
ELECTRICAL CONNECTORS MAINTENANCE
THIS WORK PACKAGE COVERS
Standard Military Connector Repair, Commercial Connector Repair, Splicing
INITIAL SETUP`
Materials/Parts
Tools and Special Tools
Flux, soldering (Item 15, WP 0305 00)
Tool kit, general mechanic's (Item 50, WP 0306 00)
Solder (Item 32, WP 0305 00)
Gun, heat (Item 17, WP 0306 00)
Tags, marker (Item 34, WP 0305 00)
Harness, wiring (Item 16, WP 0306 00)
Equipment Condition
Soldering gun (Item 41, WP 0306 00)
Master battery switch in OFF position (TM 9-2320-
302-10)
Tool kit, electrical connector repair (Item 49, WP
References
TB SIG 222
Stripper, wire, hand (Item 44, WP 0306 00)
NOTE
Tag cables and wires to aid in installation.
STANDARD MILITARY CONNECTOR REPAIR
Panel Mounting Receptacle Disassembly.
1.
a.
Unscrew nut (2) from shell (6) assembly and slide back on cable leads (1).
b.
Push grommet (3) back on cable leads (1).
c.
Drive contacts (4) out through rear of insert (5) with pin extractor.
d.
Push insert (5) out through rear of shell (6).
e.
Unsolder cable leads (1) from contacts (4).
5
6
3
4
2
1
2.
Panel Mounting Receptacle Assembly.
a.
Strip cable insulation equal to depth of solder wells of contacts (4).
b.
Slide nut (2) over cable leads (1).
c.
Slide grommet (3) over cable leads (1).
d.
Insert cable leads (1) into solder wells of contacts (4) and solder.
e.
Push insert (5) into shell (6) from rear until seated. Groove in insert must be aligned with guide in shell to ensure
proper fit.
|