TM 9-2320-302-20-2
BACKUP ALARM REPLACEMENT (M917A2) - CONTINUED
0131 00
INSTALLATION
NOTE
Perform step 1 if bracket was removed.
1.
Position bracket (16) and install three screws (13), washers (14), and nuts (15).
2.
Position backup alarm (1) on bracket (16) and install four bolts (8), eight washers (7), and four nuts (6).
3.
Feed leads (11) through holes in backup alarm (1) and install two screws (9) and new lockwashers (10).
4.
Install grommets (12).
5.
Position wiring harness clamp (2) on rear of backup alarm (1) and install bolt (5), two washers (4), and nut (3).
1
6
2
7
13
5
3
4
END OF WORK PACKAGE
0131 00-3/(-4 Blank)
|