Page Title: REMOVAL - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-302-20-2
BACKUP ALARM REPLACEMENT (M917A2) - CONTINUED
0131 00
REMOVAL - CONTINUED
2.
Remove two screws (9), lockwashers (10) and leads (11) from side of backup alarm (1). Discard lockwashers.
3.
Remove two grommets (12), and feed leads (11) through holes in backup alarm (1).
4.
Remove four nuts (6), eight washers (7), four bolts (8), and backup alarm (1) from bracket (16).
9,10
6,7,8
1
12
11
NOTE
Perform step 5 if bracket is removed.
5.
If damaged, remove three screws (13), washers (14), nuts (15), and bracket (16).
16
13,14,15